Laboratory Essential Oil Distiller

Henan Lanphan Industry Co., Ltd.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • CE Certification: Product meets CE safety and quality standards for laboratory equipment.
  • Stainless Steel Construction: Durable stainless steel material ensures corrosion resistance and longevity.
  • Portable Design: Compact and portable structure suitable for labs, schools, and hospitals.
  • Customized Voltage Options: Available in 380V and 110V configurations to match local power standards.
  • Digital Temperature Control: Precise RT-99 digital display for accurate temperature regulation.
  • High Vacuum Efficiency: Achieves up to 399.9 under 3mmHg with double sealing technology.
  • Brushless Motor: Reliable brushless motor ensures smooth operation and long service life.
  • 1-Year Warranty: Comes with a standard 1-year warranty for peace of mind.

Product Images of Laboratory Essential Oil Distiller

Laboratory Essential Oil Distiller pictures & photos
Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller pictures & photos
Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller pictures & photos
Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller pictures & photos
Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller pictures & photos
Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller pictures & photos
Laboratory Essential Oil Distiller
  • Laboratory Essential Oil Distiller
    Laboratory Essential Oil Distiller
  • Laboratory Essential Oil Distiller
    Laboratory Essential Oil Distiller
  • Laboratory Essential Oil Distiller
    Laboratory Essential Oil Distiller
  • Laboratory Essential Oil Distiller
    Laboratory Essential Oil Distiller
  • Laboratory Essential Oil Distiller
    Laboratory Essential Oil Distiller
  • Laboratory Essential Oil Distiller
    Laboratory Essential Oil Distiller

Find Similar Products

Product Description

Product Description

Laboratory Essential Oil Distiller

Model R1010 R1020 R1050
 Best Working environment 5~35
voltage 3phase, 220/380/50
Speed adjustment Digital display, dc stepless speed regulation
Rotary speed 20~130 20~110
Rotary motor Brushless 250
Temperature controlling  Digital display temperature control,RT-99
Maximum Vacuum  degree 399.9(under 3mmHg)
Rotary flask 10L 20L 50L
Flange size Ø125 Flange size Ø125 Flange size Ø125
Receiving flask 5*2 10*2 20*2
Condenser Vertical,double main condenser + auxiliary condenser, high efficiency triple-circulating condenser
Cooling area main condenser 0.84 main condenser 1.6 main condenser 1.86
secondary condenser 0.22 secondary condenser 0.39 secondary condenser 0.52
Evaporation capacity water≥5 water≥8 water≥15
alcohol≥9 alcohol≥16 alcohol≥35
Bath materials Stainless steel
Bath size Φ350×220 Φ450×260 Φ550×320
Lifting  Electric lifting
Lifting distance(mm) 0~160 0~190 0~180
Power(kW) 3 4 6.0(220V)
Dimension(mm) 920×550×1700 1250×600×2100 1320×770×2340

Laboratory Essential Oil Distiller
Laboratory Essential Oil DistillerLaboratory Essential Oil Distiller

Features of Rotary Evaporator:

1.Rotating body is composed of a reliable three-phase asynchronous motor and a transducer control device; 
2.Double sealed by PTFE and fluorine rubber sealing ring to keep high vacuum degree, separate gas and liquid and maintain no backflow; 
3.Adopt main and vice efficient condenser, there has automatic switching device between vice condenser and receiving bottle. Below receiving bottle, equipping with tapping valve, which makes it convenient to recycle solvent and the recovery rate approach to 100%; 
4.Rotary bottle is connected by nut, that is easy to install and dismount; 
5.Continuously charging and recycling material; 
6.Vacuum system is equipped with vacuum meter, choose best working vacuum degree to low boiling point materials; 
7.Heating kettle is applicable for both water and oil, digital thermostat control and manual up and down, closed resistance wire heater, temperature control by K type transducer. Besides, heating groove can move left and right; 
8.Has the function of dry burning resistant protection and safe temperature loop; 
9.Smooth starting, can positive and negative inversion operate; 
10.Durable design, can choose plate bursting disk glass component as needed.

Corollary Equipment
Laboratory Essential Oil Distiller
1. Rotary vacuum evaporator matching use with circulating water vacuum pump to offer a vacuum environment for reduced pressure distillation, they are widely used for vacuum filtration, vacuum evaporation, vacuum degassing, etc..
2. Rotary vacuum evaporator matching use with GDSZ series high and low temperature circulating pump to quickly cooling or warming, the circulating pump is an efficient equipment for quick temperature adjustment. 
3. Rotary vacuum evaporator matching use with DLSB series low temperature cooling liquid circulating pump to conduct chemical reaction and medicine storage which requires low temperature environment.

Related Products

Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller
FAQ

Q: What's the difference between vertical and inclined condenser?

A: They have no difference essentially. Vertical condenser is gradually popular because of its small space usage and convenience for transportation and use. Most high-capacity instruments use vertical condenser.

 

Q: What factor decides the working efficiency of  rotary evaporator price?

A: For same type equipment, mainly includes: steam temperature, vacuum degree and cooling water temperature. Restricted by some material's thermolability, the steam temperature may have certain limitation when working, so high vacuum degree and low cooling water temperature are two main factors for efficiency improving.

 

Q: How to select all kinds of  Thermal Rotary Evaporator?

A: As for structure, our R series products all have excellent corrosion resistance ability and leakproofness ability. According to the solvent volume, 2L, 3L, 5L's machine is fit for lab and sample test; 5L, 10L, 20L's machine is fit for medium experiment; 20L, 50L's machine is fit for medium experiment and production, especially suitable for the extraction of metal ionavoiding polluted material.

Company Information


Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller
Laboratory Essential Oil Distiller

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259508". Items marked "verified" are certified.

Watch Video
Watch Video
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Zhengzhou, Henan, China
verified Plant Area
193 square meters
verified Number of Employees
13
verified Registered Capital
1,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Qingdao Port
verified Minimum Order Quantity
1
verified Supply Chain Partners
15

Our Production Capability & Technical Expertise

Main Products
Freeze Dryer, Autoclave/Sterilizer, Spray Dryer, Solvent Recovery Machine, Rotary Evaporator, Centrifuge, Trichome Separator, Muffle Furnace, Short-Path Distillation/Closed Loop, Color Sorter
verified QA/QC inspectors
1 people
verified Inspection Type for Finished Products
Random inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Finished product checked by packing staff
verified Customization Options
Customization from Samples
verified R&D Engineers
3 people
verified Traceability of Raw Materials
No
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2016-06-21
verified Export Year
11 Years
verified Main Markets
Southeast Asia/ Mideast
verified Number of Foreign Trading Staff
8
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE

FAQ

What is the difference between vertical and inclined condensers?
They have no difference essentially. Vertical condenser is gradually popular because of its small space usage and convenience for transportation and use. Most high-capacity instruments use vertical condenser.
What factors decide the working efficiency of a rotary evaporator?
For same type equipment, mainly includes: steam temperature, vacuum degree and cooling water temperature. Restricted by some material's thermolability, the steam temperature may have certain limitation when working, so high vacuum degree and low cooling water temperature are two main factors for efficiency improving.
How to select the right Thermal Rotary Evaporator?
As for structure, our R series products all have excellent corrosion resistance ability and leakproofness ability. According to the solvent volume, 2L, 3L, 5L's machine is fit for lab and sample test; 5L, 10L, 20L's machine is fit for medium experiment; 20L, 50L's machine is fit for medium experiment and production, especially suitable for the extraction of metal ionavoiding polluted material.
What is the maximum vacuum degree achievable?
The maximum vacuum degree is 399.9 under 3mmHg, achieved through double sealing with PTFE and fluorine rubber sealing rings.
What are the available voltage options?
The equipment supports customized voltage options including 380V and 110V to suit different regional power requirements.
What is the warranty period for this equipment?
We provide a 1-year warranty for all our mechanical equipment.
Can the equipment be customized?
Yes, customization options are available from samples, including voltage and lifting stroke adjustments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now