95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested

Product Details
After-sales Service: 1 Years
Warranty: 1 Years
Condition: New

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
23
Year of Establishment
2016-06-21
  • 95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested
  • 95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested
Find Similar Products

Basic Info.

Model NO.
TFCLE-2
Name
Passive Closed Loop Extractor
Polish
Mirror Polish
System Pressure Rating
150psi
Stainless Construction
SS304 or SS316
Range of Working Temperature
-42ºC~72ºC
Volume
2 Lb
Weight
40kg
Brand
Lanphan
Transport Package
Wooden Box or Customized Packing
Specification
950mm x 460mm x 390mm
Trademark
Lanphan
Origin
China
Production Capacity
1000 Pieces Per Month

Product Description

95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested95g 1lb 304 Stainless Steel Closed Loop Hydrocarbon Oil Extractor Kit Pressure Tested

Check all valves are closed and all parts of the pipeline are connected properly
Loading. Put the hemp raw material into the extraction column, check the extraction column is sealed
Start the heating equipment (GY-5), put the E102 cooling coil into cold water
Vacuumize system. Turn on the vacuum pump (2RS-2), open all valves except the pressure relief valve, and close the vacuum valve when the pressure gauge is stable. After observing all pressure gauges are stable, confirming the system is well sealed, then close all valves.
Add the required solvent to the solvent tank (≤80% of the capacity, the limit cannot exceed 90%). The solvent volume is determined by the usage quantity of extraction columns. (put the solvent tank on the scale and determine the amount of solvent according to the weight change). The cooling coil is placed in ice water or dry ice (to keep the temperature in the heat exchanger at -7-0°C). The interlayer of the collecting tank is heated by heat transfer oil (the temperature is controlled at 43ºC-52ºC).
Open the outlet valve of the solvent tank, the inlet valve of the solvent of the extraction column, and the solvent enters the extraction column. Observe the window of the solvent tank. When the solvent no longer decreases. Close the outlet valve of the solvent tank and the inlet valve of the extraction column. Soak the material for a period of time to extract the (10-20 minutes). After soaking, open the solvent outlet valve of the extraction column. The extraction liquid is introduced into the collection tank (evaporation tank), the solvent (butane) in the collection tank evaporates, and the solvent (butane) vapor is cooled by the dryer and the condenser coil (E102) to re-liquefy and enter the solvent tank for recycling. The concentrated hemp extract will remain at the bottom of the collection tank.
Observe through the collection tank window, when no more liquid flows into the collection tank, close the outlet valve of the extraction column. Open the outlet valve of the collection tank and the inlet valve of the solvent tank, and the GY-5 is connected to the bottom of the collection tank for heating. Observe that the pressure gauges of the solvent tank and the collection tank stabilize; the collection tank stops heating; close the valves: the outlet valve of the collection pipe and the inlet valve of the solvent tank.
Transfer concentrates residues. When the collection tank stops heating, open the vent valve, open the collection tank, and transfer the concentrate to a suitable container. Then open the used extraction cartridge, take out the residue in it, and clean it. (If you continue to extract, load new hemp raw materials, repeat operations 1-7)
Clean: use HPLC grade acetone or ethanol for cleaning. Protect yourself well when acetone is used for cleaning. The step four should be done again to remove the residual ethanol in the system when ethanol is used for cleaning.
If the extraction is over, it will not be used in the short term. Open all valves to connect the entire system to the external environment. Make sure there is no backlog and clean it. Finally, clean with inert gas (available under conditions) to keep the equipment dry and clean.

FAQ
Q:Can I get some samples of passive closed loop extractor ?

A:Yes,sample order welcome.

 

Q:Could I use my own logo or design on dewaxing blast extractor ?

A:Yes.Customized logo and design on production are available.

 

Q:May I vist your factory?

A:Sure.Welcome anytime.we can also pick you up at airport and station.

 

Q: have any inventory?

A:Yes. We usually have small inventory of standard products in our warehouse.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier