After-sales Service: | 1year |
---|---|
Warranty: | 1year |
Type: | Induction Heating Machine |
Still deciding? Get samples of US$ 1148/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1200c 1800c reatment electric ceramic fiber crucible for muffle resistance furnace trade sensor
The muffle furnace is a universal heating equipment, which can be divided into box furnace, tube furnace and crucible furnace according to its appearance.
The muffle furnace is a cyclic operation type. It is used for the element analysis and determination of laboratories, industrial and mining enterprises, and scientific research units and for heating during the quenching, annealing and tempering of general small steel parts. The high-temperature muffle furnace can also be used for the sintering, dissolution, analysis and other high temperature heating of metals and ceramics.
Working Principle
The working principle of the box-type high-temperature sintering furnace (SX2 series): After the temperature measuring element thermocouple converts the temperature into an electrical signal (voltage), it is connected to the microcomputer temperature controller. The temperature controller compares this signal with the programmed value, and then the microcomputer generates a control signal that reflects the temperature change of the furnace after calculating the difference, the positive and negative values, and the time. Use this signal to drive electrical components (power modules, solid-state relays, AC contactors, etc.) to achieve the purpose of controlling the furnace temperature. The high-precision PID program is used to automatically control the entire process and digitally display the furnace temperature and process information.
According to the different heating elements used, three temperature ranges are reached, namely 1200ºC 1400ºC, and 1700ºC. At 1200ºC, molybdenum-containing resistance wires are used as heating elements. At 1400ºC, silicon carbide rods are used as heating elements. At 1700ºC, silicon molybdenum rods are used as heating elements.
Product Application
(1) Thermal processing, industrial workpiece processing, cement, building materials industries, and thermal processing or treatment of small workpieces.
(2) Pharmaceutical industry: used for drug inspection, pretreatment of medical samples, etc.
(3) Analytical chemistry industry: as sample processing in water quality analysis, environmental analysis and other fields. It can also be used for petroleum analysis.
(4) Coal quality analysis: used to determine moisture, ash, volatile content, ash melting point analysis, ash composition analysis, element analysis. Can also be used as a general ashing furnace.
Product Features
1. 30-segment intelligent temperature control regulator, PID control, temperature control accuracy is ±1 degree.
2. The temperature upper limit alarm can be set, and the main circuit can be automatically cut off when the temperature exceeds the upper limit.
3. Using high-purity alumina ceramic fiber as the furnace material, and the thermal insulation effect is good.
4. Different furnace chamber sizes can be customized according to customer requirements.
5. Simple air inlets, exhaust outlets and observation windows can be added according to customer requirements.
Product Parameters
Model | Maximum temperature(ºC) | Furnace size(mm) | Input power(V/KW) |
SX2-1-12TP | 1200ºC | 100X100X100 | 220V/1KW |
SX2-2-12TP | 1200ºC | 200X150X150 | 220V/2KW |
SX2-6-12TP | 1200ºC | 300X200X200 | 220V/6KW |
SX2-9-12TP | 1200ºC | 400X300X300 | 220V/9KW |
SX2-2-14TP | 1400ºC | 100X100X100 | 220V/2KW |
SX2-4-14TP | 1400ºC | 200X150X150 | 220V/4KW |
SX2-7-14TP | 1400ºC | 300X200X200 | 220V/7KW |
SX2-16-14TP | 1400ºC | 400X300X300 | 380V/16KW |
SX2-2-17TP | 1700ºC | 100X100X100 | 220V/2KW |
SX2-4-17TP | 1700ºC | 200X150X150 | 220V/4KW |
SX2-9-17TP | 1700ºC | 300X200X200 | 380V/9KW |
SX2-16-17TP | 1700ºC | 400X300X300 | 380V/16KW |
Product Classification
1. According to the heating elements, it is divided into: electric furnace wire muffle furnace, silicon carbide rod muffle furnace, silicon molybdenum rod muffle furnace.
2. According to the operating temperature, it is divided into: low temperature muffle furnace (electric furnace wire muffle furnace below 1000ºC), medium temperature muffle furnace (silicon carbide rod muffle furnace 1100 ~ 1300ºC), high temperature muffle furnace (silicon molybdenum rod muffle furnace 1700ºC).
3. According to the insulation materials, it is divided into two types: ordinary refractory brick muffle furnace and ceramic fiber muffle furnace.
Product Advantages
1.Adopt advanced AI artificial intelligence adjustment algorithm, no overshoot, with self-tuning function, can realize any slope rise and drop temperature control, with jump (cycle), run, pause, stop and other programmable/operable commands.
2.The input and output adopt digital correction system, the measurement is accurate and stable, and it can be extended to use non-linear sensors with any index number.
3.The second-order digital filtering function and watchdog circuit can maintain accurate measurement and stable work even in a strong interference environment.
4.Measurement accuracy: 0.2 level
5.Alarm function: upper limit, input open circuit.
6. 30/50 segment program control function.
7.Power-down protection: Due to the EPROM chip, various input data can be reliably saved even when the meter is powered off or interfered.
8.Power supply: 100 ~ 240VAC 50 ~ 60Hz
9.Power consumption: ≤ 5W
Common Faults and Solutions
Failures |
Causes |
Solutions |
Turn on the control power switch LOCK, but no power indication |
The fuse of control line FU1 2A is broken |
Check whether there is short circuit, and replace the fuse after elimination |
The green POWER indicator is off, and the red OPEN CIRCUIT indicator is on. |
The fuse of main circuit FU2 32A is broken |
Check whether there is short circuit, and replace the fuse after elimination |
Maximum voltage, but no current. |
Resistance wire fracture |
Replace the electric furnace wire |
Meter SV alternately displays Oral |
Thermocouple break |
Replace the thermocouple |
Meter SV alternately displays HIAL |
The furnace body exceeds the upper limit temperature |
When the temperature drops to the safe temperature, the meter automatically returns to normal (check the cause of overtemperature) |
Power supply and resistance wire are normal, but the furnace body can not be heated |
The control circuit is damaged |
Inform professional maintenance personnel |
Matching Products
Packaging And Shipping
Attend Exhibitions
Certificate Display
Product Service