10 Glycol Laboratory Coolling Circulating Chiller Pumps

Product Details
After-sales Service: 1year
Warranty: 1year
Type: Water-Cooled
Still deciding? Get samples of US$ 620/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
23
Year of Establishment
2016-06-21
  • 10 Glycol Laboratory Coolling Circulating Chiller Pumps
  • 10 Glycol Laboratory Coolling Circulating Chiller Pumps
  • 10 Glycol Laboratory Coolling Circulating Chiller Pumps
  • 10 Glycol Laboratory Coolling Circulating Chiller Pumps
  • 10 Glycol Laboratory Coolling Circulating Chiller Pumps
Find Similar Products

Basic Info.

Model NO.
DLSB 5L-10
Cooling Method
Air-cooled
Unit Structure
Integral
Selected Voltage
220V/50HZ
Compressor Number
1
Noise Level
Low
Application Fields
Chemical
Certification
ISO, CE
Condition
New
Name
Evaporation Chiller
Tank Volume (L)
5L
Lowest No-Load Temperature(ºC)
-15
Using Temperature Range(ºC)
5~25
Environmental Relative Humidity (%)
≤70
Transport Package
400X260X530
Trademark
lanphan
Origin
Zhengzhou
Production Capacity
5000

Product Description

10 Glycol Laboratory Coolling Circulating Chiller Pumps

Temperature Control Low-Temperature Coolant Circulation Pump

The capacity of our refrigeration pump can be 5L-500L

Temperature ranges from room temperature to -120 degrees

Product Description

10 Glycol Laboratory Coolling Circulating Chiller Pumps

 

DLSB-5 Low Temp. Cooling Liquid Circulating Pump

 

The application of DLSB low temperature pump adopts mechanical refrigeration low temperature circulating equipment and provide constant current and constant voltage circulating liquid to meet the requirement of the decreasing instrument (electric microscope, electricity probe,x-ray machine,laser reactor and accelerator) so as to guarantee the required working temperature The machine is an essential to make sure the normal working condition for the device adopting constant current and constant pressure to cool in the condition of lacking water place ,bad quality of water and higher temperature.It can provide low temperature liquid to have multiple function of chemical reaction and medicine storage collocated with rotary evaporator,vacuum drying oven,circulating water multiple pump,magnetic force stirrer.It is especially used for different kinds of chemical biology ,physical lab which needed low temperature.It is the essential lab instrument for pharmacy,food industry,metallurgical industry and college scientific research.

 

Type DLSB 5L-30°C
Tank volume (L) 24.38
lowest no-load temperature(°C) -30
Using temperature range (°C) room temperature--30
best temperature range(°C) ≤25
Environmental relative humidity (%) ≤70
Working power supply (V/HZ) single phase220/50
temperature display mode liquid crystal
temperature stability(°C) ±2
Sensor index Pt100
Instrument adjusting range (°C) ±150
set way Arbitrary adjustment of Settings in the range of use
safety protection delay,leakage,over current,over heat
  1845
  1476
Output refrigerating capacity(w) 984
  615
  246
Total machine power (W) 1350
Machine current (A) 7.2
refrigerant R404A
circulating pump 100
  20
  6
  14
opening size(mm) 260L*260
tank shape square
internal diameter and height of liquid storage tank(mm) 290*290*290
overall appearance size(mm) 565*460*845
machine weight(kg) 60
fuse 15A

 

10 Glycol Laboratory Coolling Circulating Chiller Pumps10 Glycol Laboratory Coolling Circulating Chiller Pumps
Turn on and off:

The right turn to turn on the machine: Add the appropriate refrigerating medium-connect the power with the special power supply-turn off the circulation switch-press the power button-open the circulation switch-open the refrigerator switch-open the cooling equipment
The right turn to turn off the machine.Turn off the cooling equipment-turn off the refrigerator switch-turn off the circulation switch(stirring switch)-turn off the outlet valve(or discharge the cooling medium)-turn off the power supply -disconnect circuit breaker-disconnect the power line from the power supply-clean the equipment.

Corollary Equipment

10 Glycol Laboratory Coolling Circulating Chiller Pumps

Related Products

 

The capacity of evaporation chiller can be 5L-500L
Temperature ranges  from room temperature to -120 degrees

Workshop

10 Glycol Laboratory Coolling Circulating Chiller Pumps10 Glycol Laboratory Coolling Circulating Chiller Pumps

Contact Us

 

Q: Can the mixing motor be replaced with a low-power geared motor?

A: Yes.

 

Q: What materials can be used in the reactor?

A: The material can be made of carbon steel, 304, 316, etc.

 

Q: What anti-corrosion treatment can be done inside the reactor?

A: Spray anti-rust paint or spray PTFE layer or lining enamel.

 

Q: What are the payment methods?

A: Usually we accept wire transfer, Paypal, Western Union, Alibaba International Edition Alipay and so on. The specific payment method can be discussed in the transaction process.

 

Q: How to transport industrial chiller price ?

A: It depends on the quantity and value of the goods. Usually we use international express, air and sea.

 

Q: How do I package my product?

A: Packed in a fumigation-free wooden box.

10 Glycol Laboratory Coolling Circulating Chiller Pumps10 Glycol Laboratory Coolling Circulating Chiller Pumps