Basic Info.

Model NO.
R-1020A
Material
Stainless Steel
Voltage
220V/50Hz
Lifting Stoke
120mm
Power(W)
6.3kw
Rotary Flask (L)
20L
Specification
1200*600*1900mm
Trademark
lanphan
Origin
Zhengzhou
Production Capacity
5000

Product Description

Product Description

R-1020A rotary evaporator adopts stepless speed function to make rotary flask rotates in constant speed, the

material formed a large area of thin film, then the constant temperature water bath begin to uniform heat the rotary

flask and the material is evaporated in high speed under vacuum condition, the solvent steam is refrigerated by

efficient glass condenser and received to receiving flask.

R-1020A rotary evaporator is a newly designed rotary evaporator of our company, this series has 5L, 6L, 10L, 20L,50L for selection.

R-1020A has new breakthroughs based on RE-2002 rotary evaporator

1. Equip PTFE valve between condenser and receiving flask, easy operation and good sealing.

2. Check valve control, continuous charging, available for vacuum switch in working condition. The check valve also could be replaced with hand-operated valve to convenient for operation, better sealing performance.

3. The discharging valve is made from teflon, consider of thermal expansion, other valves use glass valve element.

4. The water bath is electric lifting, lifting part use deceleration reinforcement motor, lifting process is more stable.

5. Use thicken rotary bottleneck to enhance loading bearing strength.

6. Use thicken rotary axis to enhance evaporation efficiency.

7. If the rotary evaporator sudden power lost during operation, when reconnect the power, it will automatic stop

heating.

Product Details


R-1020A Vacuum Rotary Evaporator 20L for Sale
R-1020A Vacuum Rotary Evaporator 20L for Sale
R-1020A Vacuum Rotary Evaporator 20L for Sale
R-1020A Vacuum Rotary Evaporator 20L for Sale

Product Parameters

 

Model R-1005A/R-1006A  R-1010A R-1020A R-1050A

Optimum

 Ambient 

Temperature

 (ºC)

5-35
Power(V/Hz) Single Phase 220V/50Hz(water bath&motor)
Single Phase 220V/60Hz(water bath&motor) 
Single Phase 110V/50Hz(water bath &motor)

Single Phase 220V/50Hz(water bath & motor) 
Single Phase 220V/60Hz(water bath & motor) 
Three Phase 220V/50Hz(water bath),

single phase motor 
Three Phase 380V/50Hz(water bath),

single phase motor

Main Engine 

Speed 

Regulation

Digital Display Frequency

 conversion 

stepless speedregulation

Digital Display DC stepless speed regulation

Main Engine 

Rotary

 Speed (rpm)

20 -140 20 -130 20 -110

Rotary

 Motor

 Power(W)

100 250

Temperature

 Control (ºC)

Digital display temperature control, normal temperature-180

Max vacuum

 degree (Pa)

399.9(under 3mmHg)

Rotary 

Flask (L)

5/6 Flange 050 10 Flange 0125 20Flange 0125 50 Flange 0125

Rotary Flask

 Bottleneck 

Size (mm)

40 120

Glass Rotary

 Axis 

Size (mm)

28 50

Receiving

 Flask (L)

3 5 10 20

Condenser

 Tube

main condenser,

double

 badcflow condenser

Main condenser +

subordinate 

condenser,

 double 

backflow condenser

Main condenser 

+subordinate condenser, 

three backflow condenser

Condensation 

Area

27

Main 0.42 

Subordinate 0.22

Main 0.8 

Subordinate 0.39

Main 0.91

 Subordinate0.52

Evaporative 

Capacity (L/h)

water≥2
ethyl alcdid≥5.4
water≥32 
ethyl alcohd≥8.6
water≥5
ethyl alcohol≥14.3
water≥9
ethyl alcohol≥24.5

Water 

Bath Material

Stainless Steel (Covered with Silicone Rubber Case)

Water 

Bath 

Size (mm)

Φ300xl70 Φ350x220 Φ450^260 Φ550x320
Lifting Function Electric Lifting

Lifting

 Distance (mm)

0-150 0-160 0-190 0-180
Total Power(kW) 2.2 4.8 6.3 8.3

Packing 

Dimension (mm)

950*450*1030 1100*500*1750 1200*600*1900 1400*700*2200
 
Related Product

 

R-1020A Vacuum Rotary Evaporator 20L for Sale

1. Rotary vacuum evaporator matching use with circulating water vacuum pump to offer a vacuum environment for reduced pressure distillation, they are widely used for vacuum filtration, vacuum evaporation, vacuum degassing, etc..

2. Rotary vacuum evaporator matching use with GDSZ series high and low temperature circulating pump to quickly cooling or warming, the circulating pump is an efficient equipment for quick temperature adjustment. 

3. Rotary vacuum evaporator matching use with DLSB series low temperature cooling liquid circulating pump to conduct chemical reaction and medicine storage which requires low temperature environment.
 

R-1020A Vacuum Rotary Evaporator 20L for Sale
R-1020A Vacuum Rotary Evaporator 20L for Sale

Q: What's the difference between vertical and inclined condenser?

A: They have no difference essentially. Vertical condenser is gradually popular because of its small space usage and convenience for transportation and use. Most high-capacity instruments use vertical condenser.

Q: What factor decides the working efficiency of Rotary Evaporator?

A: For same type equipment, mainly includes: steam temperature, vacuum degree and cooling water temperature. Restricted by some material's thermolability, the steam temperature may have certain limitation when working, so high vacuum degree and low cooling water temperature are two main factors for efficiency improving.

Q: How to select all kinds of Rotary Evaporator?

A: As for structure, our R series products all have excellent corrosion resistance ability and leakproofness ability. According to the solvent volume, 2L, 3L, 5L's machine is fit for lab and sample test; 5L, 10L, 20L's machine is fit for medium experiment; 20L, 50L's machine is fit for medium experiment and production, especially suitable for the extraction of metal ionavoiding polluted material. 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now