Chillers for Lab Lanphan Circulator Low Temperature Chiller

Henan Lanphan Industry Co., Ltd.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Leak-Proof Design: Uses canned motor pump to effectively solve circulating pump leakage issues.
  • Intelligent Control: Features large color touch screen for real-time temperature monitoring and control.
  • High Efficiency Cooling: Air-cooled fully enclosed compressor unit ensures high cooling and heating efficiency.
  • Easy Maintenance: Door and window type design allows convenient and quick equipment maintenance.
  • Versatile Application: Suitable for rotary evaporators, fermenters, electron microscopes, and more.
  • CE Certified: Product meets ISO and CE certification standards for safety and quality.
  • Compact Structure: Small footprint design with top-mounted fan for optimal heat dissipation.

Product Images of Chillers for Lab Lanphan Circulator Low Temperature Chiller

Chillers for Lab Lanphan Circulator Low Temperature Chiller
Chillers for Lab Lanphan Circulator Low Temperature Chiller pictures & photos
Chillers for Lab Lanphan Circulator Low Temperature Chiller
Chillers for Lab Lanphan Circulator Low Temperature Chiller pictures & photos
Chillers for Lab Lanphan Circulator Low Temperature Chiller
Chillers for Lab Lanphan Circulator Low Temperature Chiller pictures & photos
Chillers for Lab Lanphan Circulator Low Temperature Chiller
Chillers for Lab Lanphan Circulator Low Temperature Chiller pictures & photos
Chillers for Lab Lanphan Circulator Low Temperature Chiller
Chillers for Lab Lanphan Circulator Low Temperature Chiller pictures & photos
Chillers for Lab Lanphan Circulator Low Temperature Chiller
Chillers for Lab Lanphan Circulator Low Temperature Chiller pictures & photos
Chillers for Lab Lanphan Circulator Low Temperature Chiller
  • Chillers for Lab Lanphan Circulator Low Temperature Chiller
  • Chillers for Lab Lanphan Circulator Low Temperature Chiller
    Chillers for Lab Lanphan Circulator Low Temperature Chiller
  • Chillers for Lab Lanphan Circulator Low Temperature Chiller
    Chillers for Lab Lanphan Circulator Low Temperature Chiller
  • Chillers for Lab Lanphan Circulator Low Temperature Chiller
    Chillers for Lab Lanphan Circulator Low Temperature Chiller
  • Chillers for Lab Lanphan Circulator Low Temperature Chiller
    Chillers for Lab Lanphan Circulator Low Temperature Chiller
  • Chillers for Lab Lanphan Circulator Low Temperature Chiller
    Chillers for Lab Lanphan Circulator Low Temperature Chiller
  • Chillers for Lab Lanphan Circulator Low Temperature Chiller
    Chillers for Lab Lanphan Circulator Low Temperature Chiller

Find Similar Products

Product Description

product description:

The low-temperature cooling circulating pump of this equipment adopts air-cooled fully enclosed compressor unit refrigeration and microcomputer intelligent control system. The low-temperature cooling liquid circulating pump provides low-temperature circulating cooling water (liquid) flow or low-temperature constant-temperature water (liquid) flow to meet the needs of cooling water and Low temperature liquid cooling or constant temperature equipment, such as rotary evaporator, fermentation tank, electron microscope, low temperature chemical reaction kettle, electron energy spectrometer, mass spectrometer, densitometer, freeze dryer, vacuum coating instrument, reaction kettle, etc.
Chillers for Lab Lanphan Circulator Low Temperature ChillerFeatures:
The system structure is compact. Small footprint, high cooling and heating efficiency;
The large-size color touch screen can clean and display the real-time temperature changes of the Gongyi Project;
Circulating pumps and compressors can work continuously at low temperatures, control heat dissipation, and protect the system from damage;
The fan adopts a top-mounted design to meet more heat dissipation requirements;
The door and window type opening and closing design is more convenient and quick to maintain;
The circulating pump adopts a canned motor pump to solve the leakage problem of the circulating pump;
Chillers for Lab Lanphan Circulator Low Temperature ChillerPRODUCT DETAIL:
1:The large size color touch screen can clearly display the real-time temperature change during the process engineering.
2:It is convenient and quick to maintain the equipment with the door and window type opening and closing design.
3:The overhead design of the fan can meet more heat dissipation requirements.
4:It is more accurate to judge the machine faults with the display of dual pressure gauges at high and low pressure ends of the compressor.

Chillers for Lab Lanphan Circulator Low Temperature ChillerRefrigeration pump does not refrigerate troubleshooting:

First pay attention to whether the boot sequence is correct
Join the appropriate Lengjiezhi. Connect the power cord to the dedicated power supply. Close the circuit breaker. Click the "Power" button. ***Turn on the cycle switch*** Turn on the refrigeration switch. Turn on the cold storage device (the fifth and sixth are important)

Confirm that the refrigerant used is correct. In most cases, ethanol solution with a content of more than 97% is required (do not use automobile antifreeze as the refrigerant, as it will damage the life of the circulating pump if it takes a long time).
The filling of the refrigerant should be kept at the same level as the coil in the liquid storage tank, but not too much or too little (too little will affect the cooling effect of the refrigeration pump);
Confirm whether there is fluorine in the compressor: ≥30L There is a pressure gauge on the machine, you can directly see the value of the pressure gauge at this time, or directly take a photo and ask a professional to judge whether it is normal (under normal circumstances, the pressure gauge is at room temperature when the refrigeration pump is not started. It should be 8-0.9MPa in the state; if it is a dual compressor, the pressure gauge of the first-stage compressor should be 0.8-0.9MPa at room temperature, and the pressure gauge of the second-stage compressor should be 1.4-1.9MPa at room temperature); refrigeration The pressure gauge of the pump should be 0-0.25MPa in the normal starting state (the same is true for dual compressors);
If there is no fluorine deficiency in the compressor: when the refrigeration pump is stopped at room temperature, the compressor pressure gauge value is less than 6Mpa, it can be defined as fluorine deficiency, but the compressor pressure gauge value needs to be at least 0.2MPa (if the pressure is too low, it will foam water Compressor damage caused by sucking in the compressor). At this time, it is necessary to first detect whether there is a leak in the equipment. The specific method is as follows: apply soapy water, laundry detergent, detergent and other easily foaming liquids to the welding place of the copper pipe inside the compressor to observe whether there are bubbles at this time. If bubbles appear, it means that there is a leak in the pipeline and need to be repaired by professionals; after the repair, fill in according to the refrigerant type and filling method provided by our company, and then restart the machine.
It should be noted that it is forbidden to add any refrigerant to the cold storage device when the temperature of the refrigerant is reduced to the set value by the refrigeration pump.
The condenser needs to be cleaned when the refrigeration pump is slow or poorly refrigerated (clean the condenser of the refrigeration pump at least once a week to prevent clogging to prevent the refrigeration pump from being blocked by the condenser and causing the heat to be unable to remove the compressor and causing the compressor to burn)
Precautions for use:

1. Check whether the inlet and outlet valves of the refrigeration equipment are normally opened and the pressure is within the normal range.

2. Check whether the power of each device is in the on position.

3. Before using the low-temperature coolant circulation pump, add ethanol with a refrigerant concentration of ≥97% to the tank, and the liquid level of the medium should not pass the refrigeration coil in the tank.

4. Check the power supply: the power of the power supply should be greater than the total power of the instrument, and the power supply must have a good "grounding" device;

5. The equipment should be placed in a dry and ventilated place, with no obstacles within 500mm around the instrument;

6. Pay attention to the position of the liquid level in the tank. When the liquid level is too low, add refrigerant medium in time

7. When the equipment is working, the temperature of the inlet and outlet pipes is relatively high, so be careful not to touch them to prevent frostbite;

8. After use, all switches are turned off and the power supply is cut off;

9. Clean the condenser regularly to avoid the reduction of product efficiency due to excessive dust;Chillers for Lab Lanphan Circulator Low Temperature ChillerChillers for Lab Lanphan Circulator Low Temperature ChillerChillers for Lab Lanphan Circulator Low Temperature ChillerPrecautions for use:

1. Check whether the inlet and outlet valves of the refrigeration equipment are normally opened and the pressure is within the normal range.

2. Check whether the power of each device is in the on position.

3. Before using the low-temperature coolant circulation pump, add ethanol with a refrigerant concentration of ≥97% to the tank, and the liquid level of the medium should not pass the refrigeration coil in the tank.

4. Check the power supply: the power of the power supply should be greater than the total power of the instrument, and the power supply must have a good "grounding" device;

5. The equipment should be placed in a dry and ventilated place, with no obstacles within 500mm around the instrument;

6. Pay attention to the position of the liquid level in the tank. When the liquid level is too low, add refrigerant medium in time

7. When the equipment is working, the temperature of the inlet and outlet pipes is relatively high, so be careful not to touch them to prevent frostbite;

8. After use, all switches are turned off and the power supply is cut off;

9. Clean the condenser regularly to avoid the reduction of product efficiency due to excessive dust;

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR259508". Items marked "verified" are certified.

Watch Video
Watch Video
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.
Henan Lanphan Industry Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Zhengzhou, Henan, China
verified Plant Area
193 square meters
verified Number of Employees
13
verified Registered Capital
1,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Qingdao Port
verified Minimum Order Quantity
1
verified Supply Chain Partners
15

Our Production Capability & Technical Expertise

Main Products
Freeze Dryer, Autoclave/Sterilizer, Spray Dryer, Solvent Recovery Machine, Rotary Evaporator, Centrifuge, Trichome Separator, Muffle Furnace, Short-Path Distillation/Closed Loop, Color Sorter
verified QA/QC inspectors
1 people
verified Inspection Type for Finished Products
Random inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Finished product checked by packing staff
verified Customization Options
Customization from Samples
verified R&D Engineers
3 people
verified Traceability of Raw Materials
No
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2016-06-21
verified Export Year
11 Years
verified Main Markets
Southeast Asia/ Mideast
verified Number of Foreign Trading Staff
8
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE

FAQ

What type of refrigerant should be used?
Ethanol solution with a concentration of more than 97% is required. Do not use automobile antifreeze.
How should the condenser be maintained?
Clean the condenser at least once a week to prevent clogging and ensure efficient heat dissipation.
What is the cooling capacity range?
The cooling capacity ranges from 490W to 24000W depending on the specific model configuration.
Is customization available for this product?
Yes, customization from samples is available, including optional circulating pump flow and head.
What certifications does the chiller have?
The product is certified with ISO and CE standards.
What is the minimum order quantity?
The minimum order quantity is 1 unit.
How long is the lead time for production?
The average lead time is within 15 workdays for both peak and off-season periods.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed