RE-1002 rotary evaporator's rotary bottle maximum capacity is 10L, receiving bottle's maximum capacity is 5L, rotate speed is 0-140r.p.m, motor power is 180W. RE-1002 rotary evaporator(evaporating bottle volume>10L) is equipped with double condenser(main and vice condenser), which has better condensation effect and higher recovery rate. Because this rotary evaporator works under vacuum condition, and contact segment all adopt high temperature resistance material-high borosilicate glass and PTFE material, it is especially suitable for heat reactive material and material which is corrosive to stainless steel's concentration, crystallization, separation and solvent recovery.
The rotary evaporator has advantages of large contact area, high evaporation efficient, easy to handle, low noise, good sealing performance, complete in specifications and can manage easily foam material. It already has various specification products: 2L, 3L, 5L, 10L, 20L, 30L, 50L, 100L and so on, and the 100L rotary evaporator is an exclusive research and developed large-size rotary evaporator of our company, designed for the purpose of mass production need.
Product Display
Technical Parameter
Basic Parameter | Type | RE-1002 |
Glass Material | GG-17 | |
Support Material | stainless steel | |
Shell Material | Antisepsis Plastic Spraying 490*430*540mm | |
Inner Container Material | stainless steel 350*220mm | |
Baseboard Size | 474*474mm | |
Volume of Rotary Bottle | 10L ¢95 flange aperture | |
Volume of Recycling Bottle | 5L ¢50 flange aperture | |
Vacuum Degree | 0.098Mpa | |
Rotating Power | 120W | |
Rotating Speed | 0-110rpm | |
Heating Power | 3KW | |
Temperature Control Range of Bath Kettle | 400ºC | |
Temperature Accuracy | ±1ºC | |
Voltage/Frequency (V/Hz) | 220V/50Hz | |
Up and Down Distance | 180mm | |
Shape Size(mm*mm*mm) | 970*480*1950mm | |
Package Weight (KG) | 100 | |
Function Allocation | Speed Adjustment Mode | Electrodeless Speed Regulation |
Rotate Speed Display Mode | Digital Display | |
Temperature Display Mode | Digital Display K Type Sensor | |
Temperature Control Mode | Smart Temperature Control | |
Sealing Mode | PTFE Sealing | |
Condenser | Vertical efficient condenser, main condenser 120*640, assistant condenser 135*470 | |
Up and Down Mode | Manual Up and Down of Bath Kettle | |
Continuous Charging | Standard Aperture Feeding Valve | |
Vacuum Display Mode | Vacuum Meter | |
Continuous Collecting | Check valve control | |
Charging Mode | PTFE Charging valve, ¢50 flange aperture | |
Optional Equipping | Up and Down Mode | Automatic Up and Down |
Collecting Device | Double Recycling bottle | |
Anti-explosion |
Anti-explosion Frequency Changer, Anti-explosion Dynamo EX120W |
|
Frame Part | Plastic Spraying or PTFE Spraying | |
Bath Kettle Material | whole 304 stainless steel | |
Our company's laboratory glass and laboratory instruments are independent research and development, available for custom-made according to client requirements. |
Packing List of Newest Type 10L Falling Film Evaporator for Essential Oil Refining
Machine Part | Glass Part | ||
Nose | 1 set | Rotary bottle | 1 unit |
Floor shelf | 1 set | Recycling bottle | 1 unit |
Aluminum Backing Ring of Assistant Condenser | 1 unit | Main condenser | 1 unit |
Vacuum meter | 1 pc | Air conduction bottle | 1 unit |
Rotary nut | 1 set | Feeding Valve | 1 unit |
Assistant condenser nut | 1 set | ¢60 flange tap | 1 unit |
PTFE sealed joint sleeve | 1 set | 24# vent valve | 2 units |
PTFE feeding valve with flange plate | 1 set | 19# vent valve | 1 unit |
Check valve | 1 set | Rotary shaft | 1 unit |
Aluminum Backing Ring of recycling bottle | 1 unit | Assistant Condenser | 1 unit |
¢60F4 pad | 3 units | ||
¢80F4 pad | 1 unit | ||
Big black hat | 3.5 sets | ||
Transducer | 1 set | ||
Water bath kettle | 1 unit | ||
Condenser pipe clamp | 1 unit | ||
The final interpretation of this operation manual is reserved by our company. If any change in product, please be subject to the real product. The operation manual will not be changed. |
1. Rotary vacuum evaporator matching use with circulating water vacuum pump to offer a vacuum environment for reduced pressure distillation, they are widely used for vacuum filtration, vacuum evaporation, vacuum degassing, etc..
2. Rotary vacuum evaporator matching use with GDSZ series high and low temperature circulating pump to quickly cooling or warming, the circulating pump is an efficient equipment for quick temperature adjustment.
3. Rotary vacuum evaporator matching use with DLSB series low temperature cooling liquid circulating pump to conduct chemical reaction and medicine storage which requires low temperature environment.
Workshop
Q: What's the difference between vertical and inclined condenser?
A: They have no difference essentially. Vertical condenser is gradually popular because of its small space usage and convenience for transportation and use. Most high-capacity instruments use vertical condenser.
Q: What factor decides the working efficiency of vacuum rotary evaporator harga?
A: For same type equipment, mainly includes: steam temperature, vacuum degree and cooling water temperature. Restricted by some material's thermolability, the steam temperature may have certain limitation when working, so high vacuum degree and low cooling water temperature are two main factors for efficiency improving.
Q: How to select all kinds of Thermal Rotary Evaporator?
A: As for structure, our R series products all have excellent corrosion resistance ability and leakproofness ability. According to the solvent volume, 2L, 3L, 5L's machine is fit for lab and sample test; 5L, 10L, 20L's machine is fit for medium experiment; 20L, 50L's machine is fit for medium experiment and production, especially suitable for the extraction of metal ionavoiding polluted material.